Liebert® ITA2 Battery Cabinet Installer/User Guide
The VertivTM Liebert® ITA2 battery cabinet provides DC input power the Liebert ITA2 UPS. The battery cabinet may be installed in a rack or tower configuration, and a maximum of five
The VertivTM Liebert® ITA2 battery cabinet provides DC input power the Liebert ITA2 UPS. The battery cabinet may be installed in a rack or tower configuration, and a maximum of five
Standard sizes are available in 32 and 40 battery configurations to fit multiple battery sizes from a wide range of manufacturers including NorthStar Battery, East Penn (Deka), EnerSys and
Battery cabinets contain multiple 6 or 12 VDC batteries connected in series for higher voltages or in series-parallel for higher voltages and capacities. Multiple battery cabinets may be
Standard sizes are available in 32 and 40 battery configurations to fit multiple battery sizes from a wide range of manufacturers including NorthStar
Each battery string is made up of two battery cabinets that are connected to the UPS in parallel. Connect a single battery cabinet system. Refer to the illustration, “Cabling 2U Cabinets in
Battery cabinets are engineered for an uninterrupted power backup source to support the continuous operation of your critical facility.
The key to connecting the batteries is to link the positive terminal to the negative terminal, connecting each battery in series, and then leading out two power cables, one positive and
Connect the DC+ and DC- cables to the DC+ and DC- terminals. Connect the power cables in the UPS. If more battery cabinets are part of the solution, connect all battery cabinets to the UPS
For ordered cabinets as connected (battery cabinets will bolt to each other), the busbars are connected between battery cabinets with the supplied power cables.
The cabinet should be set in place after the holes are marked and drilled, and bolts are set in the correct pattern. Set and bolt one cabinet at a time to allow side access as needed.
Battery cabinets are engineered for an uninterrupted power backup source to support the continuous operation of your critical facility.
Connect the battery cable accessory to one end of the battery port on the rear panel of the UPS and connect the other end to any battery port on the rear panel of the EBC.
PDF version includes complete article with source references. Suitable for printing and offline reading.
Download detailed specifications, case studies, and technical data sheets for our ESS containers and containerized PV systems.
15 Rue des Énergies Renouvelables
Paris 75015, France
+33 1 84 83 72 76
Monday - Friday: 8:30 AM - 6:30 PM CET